Stormworks: Build and Rescue

Stormworks: Build and Rescue

Not enough ratings
Alert Controller with 2 Thresholds
   
Award
Favorite
Favorited
Unfavorite
Microcontrollers: Calculation, Microcontroller
Tags: v0.5.20
File Size
Posted
33.842 KB
4 Feb, 2019 @ 9:10pm
1 Change Note ( view )

Subscribe to download
Alert Controller with 2 Thresholds

Description
Controller accepts 1 Value that will be monitored and up to 2 Threshold values that can be checked. Greater than and Less than condition is configurable in the Properties of the Controller Block. Once Threshold 1 has been reached it will send a ON signal to the Alert 1 output. Threshold 2 is sent to Alert 2 Output. The Alert Outputs can be individually configured to Blink with separate property values set for Blink ON and Blink OFF.

Controller is ideal for situations where you want to monitor proximity distance to your Ship. You can set up Threshold 1 to be a Warning Distance and Threshold 2 to be Critical Distance. When the distance breaks Threshold 1 you can send a Warning Alert, when it breaks Threshold 2 both Warning and Critical Alerts will be issued.